Products for level measurement - Vibronic
Reliable and universal limit detection using the vibration principle.

 
Liquiphant T
 

FTL20

FTL20
Sensor length:
35 mm / 1.4"
Temperature:
-40...150 °C / -40...302 °F
Pressure:
-1...40 bar / -14.5...580 psi
Process connection:
½", ¾", 1"
Output:
AC, DC, ASi

 


More information about FTL20

FTL20H

FTL20H
Sensor length:
35 mm / 1.4"
Temperature:
-40...150 °C / -40...302 °F
Pressure:
-1...40 bar / -14.5...580 psi
Process connection:
½", ¾", 1", Triclamp, diary, flush-mounted versions
Output:
AC, DC, ASi


More information about FTL20H

FTL260

FTL260
Ambient temperature:
-40°C...+160°C (-40°F...+70°F)
Process connections:
1" NPT to ANSI B 1.20.1 316 SS
G1 A to DIN ISO 228/1, 316 SS
R1 to DIN 2999 Part 1, 316 SS
Power supply:
AC, 19...253V, 50/60Hz

More information about FTL260
Liquiphant M
 

FTL50

FTL50
Sensor length:
65 mm / 2.6"
Temperature:
-50...150 °C / -58...302 °F
Pressure:
-1...63 bar / -14.5...914 psi
Process connection:
¾", 1", flanges
Output:
AC, DC, Relay, 8/16 mA, NAMUR, PFM, PROFIBUS

 


More information about FTL50

FTL50H

FTL50H
Sensor length:
65 mm / 2.6"
Temperature:
-50...150 °C / -58...302 °F
Pressure:
-1...63 bar / -14.5...914 psi
Process connection:
¾", 1", flanges
Output:
AC, DC, Relay, 8/16 mA, NAMUR, PFM, PROFIBUS

 


More information about FTL50H

FTL51

FTL51
Sensor length:
148...6000 mm / 5.5 ...118"
Temperature:
-50...150 °C / -58...302 °F
Pressure:
-1...63 bar / -14.5...914 psi
Process connection:
¾", 1", flanges
Output:
AC, DC, Relay, 8/16 mA, NAMUR, PFM, PROFIBUS

 


More information about FTL51

FTL51C

FTL51C
Sensor length:
148...3000 mm / 5.5...118"
Temperature:
-50...150 °C / -58...302 °F
Pressure:
-1...40 bar / -14.5...580 psi
Process connection:
Flanges
Output:
AC, DC, Relay, 8/16 mA, NAMUR, PFM, PROFIBUS

 


More information about FTL51C

FTL51H

FTL51H
Sensor length:
148...6000 mm / 5.5...118"
Temperature:
-50...150 °C / -58...302 °F
Pressure:
-1...63 bar / -14.5...914 psi
Process connection:
¾", 1", flanges
Output:
AC, DC, Relay, 8/16 mA, NAMUR, PFM, PROFIBUS

 


More information about FTL51H
Liquiphant S
 

FTL70

FTL70
Sensor length:
65 mm /2.4"
Temperature:
-60...280 °C / -76...536 °F
Pressure:
-1...100 bar / -14.5...1450 psi
Process connection:
¾", 1", flanges
Output:
AC/DC, 8/16 mA, NAMUR, PFM PROFIBUS

 


More information about FTL70

FTL71

FTL71
Sensor length:
148...6000 mm / 5.8...236"
Temperature:
-60...280 °C / -76...536 °F
Pressure:
-1...100 bar / -14.5...1450 psi
Process connection:
¾", 1", flanges
Output:
AC/DC, 8/16 mA, NAMUR, PFM PROFIBUS

 


More information about FTL71
Liquiphant FailSafe
 

FDL60

FDL60
Sensor length:
130 mm / 5.1"
Temperature:
-40...150 °C / -40...302 °F
Pressure:
-1...40 bar / -14.5...580 psi
Process connection:
1", flange
Output:
PFM

 


More information about FDL60

FDL61

FDL61
Sensor length:
220...6000 mm / 8.7"...236"
Temperature:
-40...150 °C / -40...302 °F
Pressure:
-1...40 bar / -14.5...580 psi
Process connection:
1", flange
Output:
PFM

 


More information about FDL61
Soliphant T
 

FTM20

FTM20
Sensor length:
225 mm / 8.7"
Temperature:
-40...150 °C
Pressure:
-1...25 bar / -14.5...360 psi
Density:
from 200 g/l, 12 lbs/ft³
Output:
DC, AC/DC relay

 


More information about FTM20

FTM21

FTM21
Sensor length:
500, 1000, 2000 mm / 20, 40, 60"
Temperature:
-40...150 °C / -40...302 °F
Pressure:
-1...25 bar / -14.5...360 psi
Density:
from 200 g/l, 12 lbs/ft³
Output:
DC, AC/DC relay

 


More information about FTM21
Soliphant M
 

FTM50

FTM50
Sensor length:
145, 200 mm / 5.7, 8"
Temperature:
-50...150 °C / -58...302 °F
Pressure:
-1...25 bar / -14.5...360 psi
Density:
from 8 g/l / 0.6 lbs/ft3
Output:
AC, DC, AC/DC relay, 8/16 mA, NAMUR, PFM

 


More information about FTM50

FTM51

FTM51
Sensor length:
300...6000 mm / 11.8...236"
Temperature:
-50...150 °C/ -58...302 °F
Pressure:
-1...25 bar / -14.5...360 psi
Density:
from 8 g/l / 0.6 lbs/ft³
Output:
AC, DC, AC/DC relay, 8/16 mA, NAMUR, PFM

 


More information about FTM51

FTM52

FTM52
Sensor length:
750...20000 mm / 30...800"
Temperature:
-40...80 °C / -40...176 °F
Pressure:
-1...6 bar / -14.5...87 psi
Density:
from 8 g/l / 0.6 lbs/ft³
Output:
AC, DC, AC/DC relay, 8/16 mA, NAMUR, PFM

 


More information about FTM52
Nivotester
 

FTL325N

FTL325N
Power supply:
AC, 85...253V, 50/60Hz
DC, 20..60V
Ambient temperature:
Single installation -20°C...+140°C (-4°F...+60°F)
Ingress protection:
NEMA 1 (IP20)
Functional safety:
SIL 1 / SIL 2
Overspill protection:
WHG
NAMUR interface

More information about FTL325N

FTL325P

FTL325P
Power supply:
AC, 85...253V, 50/60Hz
DC, 20..60V
Ambient temperature:
Single installation -4°C...+140°C (-20°F...+60°F)
Ingress protection:
NEMA 1 (IP20)
Functional safety:
SIL 1 / SIL 2 / SIL 3 or AK 2 to 6

 


More information about FTL325P

FTL375N

FTL375N
Housing:
Monorack / Racksyst
Ambient temperature:
-20°C...+70°C
Channels:
1 to 3
Overspill protection:
WHG
External Standard:
NAMUR and others


 

 


More information about FTL375N

FTL375P

FTL375P
Housing:
Monorack / Racksyst
Ambient temperature:
-20°C...+70°C
Channels:
1 to 3
Overspill protection:
WHG
Functional safety:
SIL 1 / SIL 2 / SIL 3 or AK 2...6

More information about FTL375P


 
Print this page  |   Recommend this page  |   Bookmark this page