Specs at a glance
-
Accuracy
+/-1 mm (0.04 in)
-
Process temperature
-40 °C … +200 °C (-40 °F … +392 °F)
-
Process pressure / max. overpressure limit
Vacuum...25 bar (363 psi)
-
Max. measurement distance
80 m (262 ft)
-
Main wetted parts
PEEK or PTFE
Field of application
Micropilot FMR63B is part of the new generation of 80 GHz radar sensors. Thanks to its complete hygienic design it is suitable for continuous non-contact level measurement in hygienic applications. Wizards guide users through commissioning, proof tests and verification of the devices and thus guarantee a simple operation. Heartbeat Technology offers verification and monitoring functions to identify anomalies or checking the measurement accuracy.
The Micropilot FMR63B is for free space applications up to 80m and offers high beam focusing for vessels with many internal fittings.
Process connections: M24 adapters and hygienic process connections
Temperature: –40 to +200 °C (-40 to 392° F)
Pressure: –1 to +25 bar (-14.5 to +362.6 psi)
Maximum measuring range: 80 m (164 ft)
Accuracy: ±1 mm (0.04 in)
W-band: 80 GHz
EHEDG, 3-A, ASME BPE, International explosion protection certificates, 5- or 10-point linearity protocol
Benefits
Fulfils highest compliance requirements of the industry
Easy handling through intuitive operation and wizards, for commissioning and verification
Increased productivity thanks to process monitoring, verification also of the radar´s accuracy and diagnostics in the running process with Heartbeat Technology
Simple Display of device status – A change in the backlighting from green to red highlights errors immediately
Simple device integration into asset management systems through digital communication
Videos
-
The new generation 80 GHz radar sensors
Extended selection
-
High-end products
- Highly functional and convenient
Technical excellence
Simplicity

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Measuring principle
Level radar
-
Characteristic / Application
Premium device for continuous non-contact level measurement
with hygienic requirements (ASME BPE, USP Class VI); -
Specialities
Heartbeat Technology,
SIL 2/3 according to IEC 61508,
Bluetooth® commissioning;
Operation and maintenance with SmartBlue app;
HistoROM;
RFID TAG for easy identification;
Very narrow beam angle -
Supply / Communication
2-wire (HART/ PROFIBUS PA)
PROFINET with Ethernet-APL
Bluetooth® wireless technology -
Frequency
W-Band (~80 GHz)
-
Accuracy
+/-1 mm (0.04 in)
-
Ambient temperature
-40 °C … +85 °C (-40 °F … +185 °F)
-
Process temperature
-40 °C … +200 °C (-40 °F … +392 °F)
-
Process pressure / max. overpressure limit
Vacuum...25 bar (363 psi)
-
Main wetted parts
PEEK or PTFE
-
Process connection
Thread:
M24 -
Process connection hygienic
NEUMO BioControl;
Slotted-nut DIN11851;
Varivent;
Tri-Clamp ISO2852 -
Max. measurement distance
80 m (262 ft)
-
Communication
4...20 mA HART
Additional analog or switch output
PROFIBUS PA
PROFINET with Ethernet-APL
Bluetooth® wireless
technology and app (optional) -
Certificates / Approvals
IEC Ex, ATEX, CSA C/US, EAC Ex, JPN Ex, KC Ex,
INMETRO Ex, NEPSI Ex, UK Ex; -
Safety approvals
Overfill protection WHG;
SIL 2/ SIL 3 -
Design approvals
Acceptance test certificate 3.1, EN10204;
EU Food Contact Material (EC) 1935/2004;
US Food Contact Material FDA CFR 21;
Declaration of Conformity ASME B31.3;
Conformity to cGMP;
CoC ASME BPE;
CRN approval -
Hygienic approvals
3-A;
EHEDG;
CoC-ASME BPE -
Drinking water approvals
KTW W270;
NSF/ANSI 61 -
Options
Display,
Customized settings,
App 'SmartBlue' for commissioning and operation via Bluetooth
Gas-tight implementation;
Overvoltage protection;
PWIS free -
Application limits
Process temp. > 200°C (392°F) -> FMR62
Strong foam, stilling well and bypass (>10 m) -> FMR5x,FMP5x
-
M12-plug, MS
-
Housing/housing accessories
Drawing numberOrder code1571661118 -
Choose from our suggested options
-
-- selected coding-- selected label99.999,00<%label%>
-
Looking for more options? Please use the individual configurator to continue
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Looking for more options? Please use the individual configurator to continue
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD drawings CAD drawings
- CAD drawings
-
Prices per piece
-
<%range%><%price%>
-
- Optional add-ons
Individual configuration
Often bought together
Accessories
Related products