Standard acc. to ASTM E-230 Special acc. to ASTM E-230
Response time
63% rt = 1 s
Max. process pressure (static)
not applicable
Operating temperature range
Type T: -270 °C ...400 °C (-454 °F ...752 °F) Type J: -210 °C ...1200 °C (-346 °F ...2.192 °F) Type E: -270 °C ...1.000 °C (-454 °F ...1.832 °F) Type K: -270 °C ...1.372 °C (-454 °F ...2.500 °F) Type N: -270 °C ...1.300 °C (-454 °F ...2.372 °F)
The high modular thermometer is used for several applications with harsh environments, e.g. in Power Plants, Refineries or in the Chemical or Petrochemical industry. The robust device is designed for use within an existing thermowell. With different head transmitter it's a complete unit ready for use with enhanced measurement accuracy and reliability.
The sensor assembly can be used in process industries such as:
Chemicals
Petrochemical
Refineries
Offshore Platforms
Benefits
FM/CSA XP Class I, Div. 1 approved temperature assemblies for maximum safety
One source shopping for temperature measurement solutions. World class transmitter with integrated sensor offering for heavy process industry applications
Remove and install straight out of the box!
Improved galvanic isolation on most devices (2 kV)
Simplified model structure: Competitively priced, offers great value. Easy to order and reorder. A single model number includes sensor, thermowell and transmitter assembly for a complete point solution
All iTEMP® transmitters provide long term stability ≤0.05% per year
Iplom SpA sought to optimize its refining process to extend catalyst life and to increase safety in a hydrodesulfurization (HDS) application through precise 3D temperature profiling.
Explosion Proof US style modular temperature assembly for heavy duty applications with extension to be used with existing thermowell
Thermowell / protection tube
to use with thermowell
Insert / probe
mineral insulated (MI), flexible
Outer diameter protection tube / Insert
1/4'' (6,35 mm) 3/8'' (9,53 mm)
Max. immersion length on request
up to 100" (2540 mm) others on request
Material protection tube/ thermowell
Sensor sheath 316 Alloy 600
Optional coating
not applicable
Process connection
Thermowell connection male thread: NPT1/2"
Tip shape
straight
Surface roughness Ra
not applicable
Operating temperature range
Type T: -270 °C ...400 °C (-454 °F ...752 °F) Type J: -210 °C ...1200 °C (-346 °F ...2.192 °F) Type E: -270 °C ...1.000 °C (-454 °F ...1.832 °F) Type K: -270 °C ...1.372 °C (-454 °F ...2.500 °F) Type N: -270 °C ...1.300 °C (-454 °F ...2.372 °F)
Max. process pressure (static)
not applicable
Accuracy
Standard acc. to ASTM E-230 Special acc. to ASTM E-230
Response time
63% rt = 1 s
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex
Active barrier, 1 channel for 4 to 20 mA, HART® transparent with 24 to 230 V AC/DC as well as active/passive input and output, optionally with SIL and Ex