Specs at a glance
-
Accuracy
Rod probe: +/- 2 mm (0.08 in)
Rope probe: +/- 2 mm (0.08 in) -
Process temperature
-20...+80 °C
(-4...+176 °F) -
Process pressure / max. overpressure limit
Vacuum...6 bar,
(Vacuum...87 psi) -
Max. measurement distance
Rod: 4 m (13 ft) Min DK>1.6
Rope: 12 m (40 ft) Min DK>1.6 -
Main wetted parts
Rod probe: 316L, PPS, Viton
Rope probe: 316, PPS, Viton
Field of application
Levelflex FMP50 is the instrument for basic applications in liquids which do not place high demands on temperature and pressure ranges or chemical resistance. Particularly in basic supply or storage applications as well as utility processes FMP50 is the best choice. Levelflex FMP50 guided radar is used for continuous level measurement of liquids, pastes and slurries. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.
Version with rod or rope probe.
Process connections: Thread or adapter flange
Temperature: -20 to +80°C (-4 to +176°F)
Pressure: -1 to +6bar (-14.5 to +87psi)
Maximum measuring range: Rod 4m (13ft), rope 12m (39ft)
Accuracy: ±2mm (0.08")
International explosion protection certificates, overfill prevention WHG, SIL, 5-point linearity protocol
Benefits
Reliable measurement even for changing product and process conditions
HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
Highest reliability due to new Multi-Echo Tracking evaluation
Hardware and software developed according to IEC 61508 up to SIL3
Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle
Seamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)
World's easiest proof test for SIL and WHG saves time and costs
Videos
Lean selection
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
| FLEX selections | Technical excellence | Simplicity |
|---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
-
-
Technical Information (TI)
TI Weld-in adapter, process adapter and flanges
Level, pressure and temperature measurement
EN 15/09/202328/10/202130/07/202119/06/202008/11/2019Language:
English
Version:
15/09/2023
File size:
2.9 MB
File name:
TI00426FEN_2423.pdf
-
-
-
Technical Information (TI)
TI Levelflex FMP50
Guided-wave radar
EN 01/10/202422/02/202330/06/202231/07/202012/04/2018Language:
English
Version:
01/10/2024
File size:
3.1 MB
File name:
TI01000FEN_2724-00.pdf
-
-
-
Operating Instruction (BA)
BA Levelflex FMP50 FOUNDATION Fieldbus
导波雷达液位计
EN 01/10/202421/02/202330/06/202214/12/2012Language:
Chinese
Version:
01/10/2024
File size:
6.2 MB
File name:
BA01051FZH_0924-00.pdf
-
-
-
Operating Instruction (BA)
Levelflex FMP50 HART Operating Instructions
Guided wave radar
EN 12/04/2018Language:
English
Version:
12/04/2018
File size:
4.3 MB
File name:
BA01000FEN_2018.pdf
-
-
-
Operating Instruction (BA)
Levelflex FMP50 PROFIBUS PA Operating Instructions
Guided wave radar
EN 12/04/201809/11/201715/12/2016Language:
English
Version:
12/04/2018
File size:
3.7 MB
File name:
BA01005FEN_1718.pdf
-
-
-
Device Parameter (GP)
Levelflex FMP5x HART Description des paramètres d'appareil
Radar de niveau filoguidé
EN 28/04/2016Language:
French
Version:
28/04/2016
File size:
3.3 MB
File name:
GP01000FFR_1616.pdf
-
-
-
Short Instruction (KA)
Levelflex FMP50 HART Brief Operating Instructions
Guided wave radar
EN 12/04/201830/11/201717/11/201712/02/2015Language:
English
Version:
12/04/2018
File size:
2.1 MB
File name:
KA01053FEN_1918.pdf
-
-
-
Short Instruction (KA)
Screw set for Micropilot II/M, Levelflex M, Prosonic M
Screw set for Micropilot II/M, Levelflex M, Prosonic M
EN 15/04/2021Language:
English
Version:
15/04/2021
File size:
532.2 KB
File name:
KA00512F00_A2.pdf
-
-
-
Short Instruction (KA)
Levelflex FMP50 PROFIBUS PA
Radar falowodowy
EN 05/04/202212/04/2018Language:
Polish
Version:
05/04/2022
File size:
1.2 MB
File name:
KA01071FPL_1722-00.pdf
-
-
-
Short Instruction (KA)
Levelflex FMP50 FOUNDATION Fieldbus
Geführtes Radar
EN 30/06/2022Language:
German
Version:
30/06/2022
File size:
1.2 MB
File name:
KA01106FDE_0622-00.pdf
-
-
-
Installation Instructions (EA)
Set housing security clamp Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200,EN 31/08/201707/10/2013Language:
English
Version:
31/08/2017
File size:
279.5 KB
File name:
EA00038FA2_1717.pdf
-
-
-
Installation Instructions (EA)
Display module Installation Instructions
Levelflex FMP5x, Micropilot FMR5x
EN 08/06/2018Language:
English
Version:
08/06/2018
File size:
345.1 KB
File name:
EA01247FA2_0118.pdf
-
-
-
Installation Instructions (EA)
Set HF cable for compact and remte versions Installation Instruction
Levelflex
EN 17/07/202010/02/2015Language:
English
Version:
17/07/2020
File size:
1.8 MB
File name:
EA00059FA2_0320.pdf
-
-
-
Installation Instructions (EA)
Cover Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200, Remote display FHX50EN 28/06/201828/02/201718/11/2015Language:
English
Version:
28/06/2018
File size:
517.9 KB
File name:
EA00035FA2_2018.pdf
-
-
-
Installation Instructions (EA)
Main electronics module Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x
EN 31/08/201714/04/2014Language:
English
Version:
31/08/2017
File size:
281.5 KB
File name:
EA00041FA2_1617.pdf
-
-
-
Installation Instructions (EA)
EA Housing GT18, GT19, GT20
Levelflex, Micropilot
EN 19/12/2025Language:
English
Version:
19/12/2025
File size:
842.9 KB
File name:
EA01340FEN_0225-00.pdf
-
-
-
Installation Instructions (EA)
Housing filter Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200,EN 31/08/201718/11/2015Language:
English
Version:
31/08/2017
File size:
225.7 KB
File name:
EA00037FA2_2117.pdf
-
-
-
Installation Instructions (EA)
Sealing set Installation instruction
Levelflex, Micropilot, Promass 200, Prosonic Flow 200, Promag 200,
Prowirl 200EN 22/06/2015Language:
English
Version:
22/06/2015
File size:
1020.9 KB
File name:
EA00036FA2_1715.pdf
-
-
-
Installation Instructions (EA)
Terminal set Installation instruction
Levelflex, Micropilot, Promass 200, Prosonic Flow 200, Promag 200,
Prowirl 200EN 07/10/2013Language:
English
Version:
07/10/2013
File size:
530.8 KB
File name:
EA00040FA2_1613.pdf
-
-
-
Installation Instructions (EA)
Transmitter electronics FHX50 Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200,EN 02/07/201831/08/201726/01/2015Language:
English
Version:
02/07/2018
File size:
652.3 KB
File name:
EA01064FA2_0518.pdf
-